Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med. oral patol. oral cir. bucal (Internet) ; 26(1): e8-e13, ene. 2021. graf
Artigo em Inglês | IBECS | ID: ibc-200532

RESUMO

BACKGROUND: Whole Slide Imaging (WSI) is an alternative method to light microscopy (LM). However, few studies have compared the diagnostic agreement between WSI and LM, especially to grade oral epithelial dysplasia (OED). The purpose of this study was to evaluate the variability in grading OED by the World Health Organization grading system, using WSI and conventional LM, and to investigate whether the access to clinical information, and psychologic or physical states of the pathologists could interfere with the diagnosis. MATERIAL AND METHODS: eleven experienced pathologists from seven Brazilian universities independently evaluated twenty-five OED cases. The analyses were performed in duplicate for each method, with an interval of at least 30 days, and the time consumed in each analysis was measured. Physical and psychologic states were evaluated by blood pressure levels, heart rate and two questionnaires: State-Trait Anxiety Inventory and Perceived Stress Scale. Clinical information was provided after the second evaluation using WSI and the pathologist could change their diagnostic decision or not. RESULTS: LM showed a higher inter-examiner agreement (k=0.53) than WSI (k=0.45) and a smaller time consumed by the pathologists (mean of 65.53 seconds compared to 91.02 seconds in WSI). In the first analysis using conventional microscopy, there was a positive correlation between kappa values and anxiety (r=0.47, p = 0.02), and stress (r=0.64, p < 0.01), and an inverse correlation with heart rate (r=-0.48, p = 0.02). In the digital analysis, there was also a positive correlation between kappa values and anxiety (r=0.75, p < 0.001). After clinical information was given, there was a slight change in 11.3% of the cases, and a great discrepancy in 1.1% of the cases, mainly increasing the OED grade. CONCLUSIONS: both microscopy systems had similar results, although LM had slightly higher kappa values, and WSI was more time consuming


No disponible


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Doenças da Boca/patologia , Mucosa Bucal/patologia , Lesões Pré-Cancerosas/patologia , Processamento de Imagem Assistida por Computador/métodos , Microscopia/métodos , Doenças da Boca/diagnóstico , Lesões Pré-Cancerosas/diagnóstico , Fatores de Tempo , Variações Dependentes do Observador , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...